Version 1.1.1 dated February 25th, 2013
Page 64
Original operating instructions
GB
7
Position display, inte rnal parameter settings
7.1
Programming function
Introduction of the function:
Setting the counting direction of the line error compensation coefficient and the resolution of
the axes.
Proceeding:
Go back to the standard display mode;
Press the key
for 5 seconds until the display of the X axis displays "P-10",
which shows that you are in the programming mode. Now the Z axis displays"0" (the Y
axis for the 2-axis position display) which means that you where currently in the mode to
set the counting direction.
Press the digit keys, the key
and the key
in order to enter the new
programming values (= Parameters). When there is no modification for the displayed
parameter skip this step;
Press the key
to switch over to the following parameter. By pressing this key the
previous parameter value resp. its modification is simultaneously confirmed. After the
first switching on also the X axis value "P-11" would be displayed. The Z axis (resp. the
Y axis for the 2-axis position display) displays the following programming value which is
assigned to the parameter "P-11".
Repeat the above mentioned steps and enter all programming values one after another.
Remark:
- Press the key
at any time in order to quit the programming mode.
- During the process of parameter entry you can press the key
in order to delete
the entry.