Construction and function of the basic machine
5.15.4
Suction port for filling the spray liquid tank (optional)
Fig. 58/...
(1) Suction hose (8 m, 3").
(2) Quick coupling.
(3) Suction filter for filtering the intake water.
(4) Non-return valve. Prevents liquid already in
the spray liquid tank from running out if the
vacuum suddenly collapses during the filling
process.
Fig. 58
5.15.5
Filling connection for filling the spray liquid tank with pressure (option)
•
Filling with free flow path and swivel spout
(Fig. 59).
•
Return flow safe direct filling, not approved
for filling from a public water supply net-
work.
Fig. 59
Fig. 60
•
Switch tap with filling connection (Fig. 60).
(5) Automatic fill stop with button for manual
termination of the filling (optional)
88
UX Super
BAG0054.10 11.16