Using the machine
10.2.4
Adding the agent using ECO-Fill
1. Activate the pump.
2. Couple the ECO-Fill container with ECO-Fill
connection.
3. Move the pressure gauge switch tap
A
to
position
.
4. Move switch tap
D
to open.
5. Move switch tap
E
and
F
to position
0
.
6. Move switch tap
O
to position
1
.
→
Evacuate the ECO-Fill container.
7. Move switch tap
O
to position
0
when the
desired quantity has been evacuated from
the ECO-Fill container.
Fig. 139
Rinsing the ECO-Fill counter:
1. Decouple the hose from the ECO-Fill con-
tainer and couple it to the flushing foot.
2. Move switch tap
O
to position
1
.
→
The counter is flushed.
3. Move switch tap
O
and
D
back to 0 and
disconnect the counter.
UX Super
BAG0054.10 11.16
167