Construction and function of the basic machine
5.15.1
Fill level indicator on the machine
The fill level indicator shows the tank capacity [l]
in the spray liquid tank
The fill level on the machine is shown
•
electronically (Fig. 87/1) (optional)
•
mechanically (Fig. 87/2)
Fig. 55
5.15.2
Agitators
The field sprayer has a main agitator and an
additional agitator. Both agitators are designed
as hydraulic agitators. The additional agitator is
also combined with pressure filter rinsing for the
self cleaning pressure filter.
The main agitator has its own agitator pump. The
additional agitator is supplied by the operation
pump.
When the agitators are switched on, they mix the
spray liquid in the spray liquid tank, thereby
providing a homogeneous spray liquid. The stir-
ring performance can be infinitely adjusted.
The stirring performance is adjusted
•
using switch tap
H
for the main agitator on
the setting tap.
•
using switch tap
I
for the additional agitator
on the setting tap.
To switch off the relevant agitator, turn the set-
ting tap to position
0
.
The fastest stirring performance is available in
position
1
.
Safety device for drainage function on the pres-
sure filter (Fig. 56/2).
Fig. 56
86
UX Super
BAG0054.10 11.16