Using the machine
10.5.1
Cleaning the sprayer with the tank empty
•
Clean the spray liquid tank on a daily basis!
•
The flushing water tank must be filled completely.
•
The cleaning process should be carried out in a threefold reduc-
tion procedure.
1. Activate the pump, adjust pump speed to
450 rpm.
2. Manually move suction chest
G
to position
.
3. Move the pressure gauge switch tap
A
to
position
.
4. Open the agitator(s)
H, I
completely.
→
Flush the agitator with 10% of the flushing
water supply.
5. Switch off agitator(s)
H, I
.
DUS: Spray lines are flushed automat-
ically. Use 10 % of the flushing water
supply for this purpose.
6. Move the pressure gauge switch tap
A
to
position
.
7. Open switch tap
B
.
→
Carry out the internal cleaning with 10% of
the flushing water supply.
8. Close switch tap
B
.
9. Manually move suction chest
G
to position
.
10. Move the pressure gauge switch tap
A
to
position
.
11. Spread the diluted residues on the area
already treated while driving.
12. Switch the sprayer off and back on again
several times for a few seconds via the on-
board computer.
The valves and the return lines are
flushed by this switching on and off.
→
Keep spreading the diluted residues until
only air comes out of the nozzles.
180
UX Super
BAG0054.10 11.16