Fault
ISOBUS field sprayer BAG0171.9 11.20
95
F15014
Warning Missing change of the signal value of
the suction tap position detection
during simultaneous activation of the
setting motor
•
Check the connection cable and motor of the
suction tap adjustment element
•
Check the suction tap position monitoring
•
Check the suction tap mechanism
F15015
Warning Spring suspension computer sends a
sensor signal for detecting the left
spring position (rear) that is outside
the permissible signal range of 2 to
22 mA
•
Check the height detection on the axle and
check the connection cable
F15016
Warning Spring suspension computer sends a
sensor signal for detecting the right
spring position (rear) that is outside
the permissible signal range of 2 to
22 mA
•
Check the height detection on the axle and
check the connection cable
F15017
Warning The spring suspension computer
reports that the height of the left and
right axle are different.
•
Check the oil supply
•
Check the spring suspension valves
•
Check the height detection on the axle and
check the connection cable
•
Use the Diagnostics menu to check if the con-
nections of the potentiometer for the height ad-
justment have been swapped, or if they have
been swapped when connecting left and right
hydraulic valves.
F15018
Warning An error has been detected in the
runtime monitoring of the spring
suspension job computer.
•
Restart the implement
•
Check the spring suspension job computer con-
nection cable
•
Check fuse F7
F15019
Warning Voltage value of the pressure sensor
for pressure control / rate control is
outside the permissible signal range
of 0.5 V to 4.5 V
•
Check the pressure sensor and connection ca-
ble.
F15020
Warning Although at least one part width
section valve is open and a pressure
of >2 bar is applied, the flow meter
does not send a signal
•
Check the flow meter and connection cable
•
Check the pressure sensor
F15021
Warning Although the bypass valve is open
and a pressure of >2 bar is applied,
the flow meter does not send a sig-
nal
•
Check the flow meter and connection cable
•
Check the return flow control valve
•
Check the pressure sensor
F15022
Warning Although at least one part width
section valve is open, HighFlow is
activated, and a pressure of >2 bar is
applied, the flow meter does not
send a signal
•
Check the flow meter and connection cable
•
Check the pressure sensor
F15023
Warning An error has been detected in the
runtime monitoring of the AmaSwitch
job computer.
•
Restart the implement
•
Check the AmaSwitch job computer connection
cable
•
Check the fuse for the ISOBUS load on the trac-
tor
F15024
Warning The fill level sensor's current is out-
side of the permissible signal range
from 2...22 mA
•
Check the potentiometer and connection cable of
the fill level sensor
•
Liquid in the front tank can be pumped by press-
ing and holding the respective direction button