Settings
60
ISOBUS field sprayer BAG0171.9 11.20
•
Determine the calibration value "Pulse flow meter".
ο
Annually.
ο
After removal of the flow meter.
ο
After longer periods of operation, because spray residue
deposits can form in the flow meter.
ο
If differences occur between the required spray rate and the
actual spray rate.
alibrating flow meter 1:
1. Fill the spray liquid tank with clear fresh
water (approx. 264 gal / 1000 l)
2.
3. Drive the pump at operating speed.
4.
5.
Switch on spraying and apply the
displayed minimum quantity.
→
The values of the "Pulses" for the amount of
water applied are measured continuously
and shown on the display.
6.
Switch off spraying and interrupt the
pump drive.
7. Precisely determine the amount of water
applied by refilling the spray liquid tank
ο
using a measuring vessel,
ο
by weighing or
ο
using a water gauge.
CALIBRATING FLOW METER 1
Fill a particular amount of water into the sprayer and
set the nominal pump speed!
Tank fill level
0 gal / l
264 gal.
/
1000 l
Nominal pump speed
0 rpm
540 rpm
8. Enter the value for the amount of water
determined.
9.
Confirm entry.
→
The calculated calibration value is dis-
played.
10.
Save calibrated value.
CALIBRATING FLOW METER 1
Switch off the sprayer and enter the sprayed quanti-
ty.
Sprayed quantity
Pulses determined
9999
Nominal pump speed
0
rpm