![Amazone Pantera 4503 Operating Manual Download Page 101](http://html1.mh-extra.com/html/amazone/pantera-4503/pantera-4503_operating-manual_2919770101.webp)
Fault
ISOBUS field sprayer BAG0171.9 11.20
101
F15096
Note
Alert for emergency activation. Appears
when the position detection of the suction
tap motor or the suction tap motor itself
has failed.
---
F15097
Note
Alert for emergency activation. Appears
when the position detection of the suction
tap motor or the suction tap motor itself
has failed.
---
F15098
Note
Alert for emergency activation. Appears
when the position detection of the suction
tap motor or the suction tap motor itself
has failed.
---
F15099
Note
This message appears when the base
computer (AEL652) no longer receives
messages from the Comfort Package Plus
job computer (AEL051).
•
Check the CAN bus connection
•
Check the Comfort Package Plus job
computer (AEL051)
•
Contact your AMAZONE service partner
F15100
Note
---
•
Check the CAN bus connection
•
Check the Comfort Package Plus job
computer (AEL051)
•
Contact your AMAZONE service partner
F15101
Note
---
•
Check the CAN bus connection
•
Check the Comfort Package Plus job
computer (AEL051)
•
Contact your AMAZONE service partner
F15102
Warning
Position detection signal of the left inner
boom section is outside the permissible
signal range of 2 to 22 mA
•
Check the sensor and sensor connec-
tion
•
Check the sensor connection line
•
Check fuse F2
•
Check fuse F6
F15103
Warning
Position recording signal for the right inner
boom is outside the permissible signal
range of 2 to 22 mA
•
Check the sensor and sensor connec-
tion
•
Check the sensor connection line
•
Check fuse F2
•
Check fuse F6
F15104
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "spray line" valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15105
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the valve for the oil
motor of the flushing water pump.
•
Check the valve connection line
•
Check the valve coil
F15106
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the valve for the sec-
ondary agitator.
•
Check the valve connection line
•
Check the valve coil
F15107
Warning
Position detection signal for the center
boom A on the left is outside the permis-
sible signal range of 2 to 22 mA
•
Check the sensor and sensor connec-
tion
•
Check the sensor connection line
•
Check fuse F2
•
Check fuse F6