![Amazone Pantera 4503 Operating Manual Download Page 103](http://html1.mh-extra.com/html/amazone/pantera-4503/pantera-4503_operating-manual_2919770103.webp)
Fault
ISOBUS field sprayer BAG0171.9 11.20
103
F15120
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "spray liquid tank
pump to induction bowl" valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15121
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "Ecofill" valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15122
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "flushing water
pump to spray liquid area" valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15123
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "spraying pump
pressure range shut-off valve".
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15124
Warning
An excessive current consumption / or no
current consumption during activation has
been detected on the "filling line shut-off
valve".
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15125
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "internal cleaning"
valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15126
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "induction bowl"
valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15127
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "external cleaning"
valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15128
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "induction bowl
cleaning" valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15129
Warning
Excessive current consumption / or no
current consumption during activation has
been detected on the "internal cleaning
via spraying pump" valve.
•
Check the valve connection line
•
Check the valve in the liquid path for
foreign objects
F15130
Warning
The signal of the flushing water pump
speed sensor is outside the permissible
signal range of 2 to 7 mA or 17 to 20 mA
•
Check the sensor and measuring sur-
face for contamination
•
Check the switching distance of the
sensor
•
Check the connection line to the sensor
•
Check fuse F2
•
Check fuse F1
F15131
Warning
Position detection signal of the right outer
boom is outside the permissible signal
range of 2 to 22 mA
•
Check the sensor and installation
•
Check the connection line to the sensor
•
Check fuse F2
•
Check fuse F1
F15132
Warning
The signal of the induction bowl suction
setpoint generator is outside the permis-
sible signal range of 2 to 22 mA
•
Check the connection line to the sensor
•
Check fuse F2
•
Check fuse F1