![Amazone Pantera 4503 Operating Manual Download Page 59](http://html1.mh-extra.com/html/amazone/pantera-4503/pantera-4503_operating-manual_2919770059.webp)
Settings
ISOBUS field sprayer BAG0171.9 11.20
59
5.1.2
Spray liquid circuit
<
SPRAY LIQUID CIRCUIT
•
Front tank
ο
Front tank with FlowControl in use
ο
Front tank not in use
Front tank
•
Enter the minimum fill level in the spray
liquid tank when spraying (10-40%).
The minimum fill level in the spray liquid
tank is maintained via the front tank.
→
This can affect the front axle load of the
tractor.
Min. fill level in the spray
liquid tank when spraying
Flow meter 1
Flow meter 2 (return flow meter)
Flow meter 3 (High Flow+)
•
Enter the pulses for the flow meter
(0-9999)
•
Calibrate flow meters
Pulses
flow meter 1
Calibrate
flow meter 1
Pulses
flow meter 2
Calibrate
flow meter 2
Pulses
flow meter 3
Calibrate
flow meter 3
Calibrating flow meters
•
The machine computer needs the calibration value "Pulse flow
meter" for the flow meter / return flow meter to determine and
control the rate.
•
You must determine the calibration value "Pulse flow meter" via
a calibration procedure of the flow meter / return flow meter, if
the calibration value is not known.
•
You can enter the calibration value, "Pulse flow meter" for the
flow meter / return flow meter manually if you know the precise
calibration value.