![Amazone Pantera 4503 Operating Manual Download Page 105](http://html1.mh-extra.com/html/amazone/pantera-4503/pantera-4503_operating-manual_2919770105.webp)
Fault
ISOBUS field sprayer BAG0171.9 11.20
105
F15149
Warning The ContourControl job computer has
detected a problem with the tilt adjustment
•
Check the hydraulic cylinder / valves of
the tilt adjustment unit
•
Check the tilt cylinder pressure sensors
•
Check the connection cable
•
Restart the implement
F15150
Warning The ContourControl job computer has
detected a problem with the left boom
angling up
•
Check the lifting cylinder/valves for an-
gling up on the left
•
Check the connection cable
•
Check the angling up potentiometer
•
Check fuse F2
•
Restart the implement
F15151
Warning The ContourControl job computer has
detected a problem with angling up the
boom on the right
•
Check the lifting cylinders / valves for
angling up on the right
•
Check the connection cable
•
Check the angling up potentiometer
•
Check fuse F2
•
Restart the implement
F15152
Warning The ContourControl job computer has
detected a problem with the boom folding
on the left
•
Check the hydraulic cylinders/valves for
inner boom folding on the left
•
Check the connection cable
•
Check the inner boom folding potentiome-
ter on the right
•
Check fuse F2
•
Restart the implement
F15153
Warning The ContourControl job computer has
detected a problem with boom folding on
the right
•
Check the hydraulic cylinders / valves for
inner boom folding on the right
•
Check the connection cable
•
Check the inner boom folding potentiome-
ter on the right
•
Check fuse F2
•
Restart the implement
F15154
Warning The ContourControl job computer has
detected a problem with the SwingStop
system
•
Check the hydraulic cylinders / valves for
inner boom folding on the right
•
Check the connection cable
•
Check the SwingStop oscillating path
potentiometer
•
Check the yaw rate sensors in the boom
•
Check fuse F2
•
Restart the implement
F15155
Warning The implement has detected that not all of
the control units have not been properly
switched off since the last shut-down of
the system.
•
The ISOBUS load voltage from the tractor
is not switched off, check the tractor
•
If necessary retrofit the AMAZONE isolat-
ing relay (NL1084)
F15156
Warning The signal of the transport position sensor
is outside the permissible signal range of 2
to 7 mA or 17 to 22 mA
•
Check sensor BEL372
•
Check the sensor connection cable
•
Check fuse F1
•
Check fuse F2