RE220002 Rev. 6
26
Disassembly Procedures
To avoid risk of electrical shock, personal injury, or death,
disconnect power to unit and discharge capacitor(s)
before following any disassembly procedures.
WARNING
!
Component Module Panel Removal
(Model VEND-10.F, .G, .H, .J, VEND-10, VEND-11
1. Remove the control panel assembly.
2. Remove two interlock switch module screws and
remove the switch module. Do not disconnect wires
to the switch module.
3. Remove the nut at the top of the component module
panel. Pull the top of the panel away from the cavity
wall until it clears the stud.
4. Pull the component module panel toward the front of
the oven and lift up to separate the two tabs from
slots in the oven base.
5. Slowly pull the interlock switch module and
component module panel through the control panel
opening. Move wires around as required to clear the
opening.
NOTE: After replacement, perform interlock switch
module adjustment. Perform Radio Frequency
Leakage Test Procedures.
Stirrer Cover Removal
Stirrer Assembly Removal
NOTE: Formed washers were used on early production
only. Formed washers are not used with
replacement stirrer blades.
NOTE: If installed, formed washers must be installed as
shown.
NOTE: Check oven for leakage to ensure less than 4
mw/cm
2
leakage at 5 cm.
NOTE: Radio Frequency gasket must be installed as
shown.