Operating Instructions PA-xxP
961-00035 rev11
8/42
3
Commissioning
3.1
Electrical Connections
DO
Use a properly rated Mains Service Supply
An identification plate on the rear panel specifies the input mains voltage
requirement.
DO
Provide Proper Ventilation
DO
Use Lifting Gear to Move the Unit
DO NOT
Operate Machine Without Covers
DO NOT
Operate With Suspected Failures
DO NOT
Operate in an Explosive Atmosphere
DO NOT
Operate in Wet/Damp Conditions
IF IN DOUBT, CONTACT YOUR DISTRIBUTOR
Inspect the unit for any shipping damage prior to connecting to the mains supply.
Ensure you use green safety goggles when operation unit.
Maximum inlet gas pressure : 0.03Mpa
Caution
This product MUST be connected to the correct mains supply voltage. Refer to the
identification plate located on the rear panel.
Single-Phase connections :
BROWN :
Live
BLUE :
Neutral
GREEN/YELLOW :
Safety Earth / Ground
Three-Phase connections :
BLACK 1, BLACK2, BLACK3 :
Phase colours
GREEN/YELLOW :
Safety Earth / Ground
Ensure a good earth / ground connection is provided for operator safety. The internal
electrical circuits are earthed. To comply with Class 1 protection, the positive output
terminal should be earthed
.
The unit must NOT be operated with any of the negative outputs grounded.
Ensure unused negative outputs have the supplied protection covers fitted.