Operating Instructions PA-xxP
961-00035 rev11
29/42
Energy Graph.
Each time the welder does a weld on each of the outputs, the energy
readout is recorded for display on the energy trend graph. The welder will record the
energy readings from the last 1000 welds, and then automatically roll round and over
write the oldest data. It is possible to expand the y-axis to ‘zoom’ into the waveform for
more detailed examination.
The screen will show the last 100 welds, and then automatically scroll to the left. To view
older data, press the DISP button, the realtime display updates are switched off,
however, the data is still recorded for all new welds. Pressing the PREV or FWD buttons
will scroll along the historical data, 10 welds at a time. Pressing the DISP button again,
will revert to the realtime display, including any welds done while in the historical mode.
The energy readouts on the left are updated after each weld.
Exit returns to
monitor menu.
Scale for upper
Y axis. 0 to
999.9 Joules.
Scale for lower Y
axis. 0 to 999.9
Joules.
Key to graph
lines. White is
pulse 1.
Last Energy readout
for pulse 1.
The welder
records energy
readings for the
last 1000 welds,
then rolls round.
The graph/window
will show the last
100 welds.
Press to
enable the
scroll buttons
to move
through the
historical
data. Press
again to revert
to realtime
display.
Press to scroll
forwards
through the
data file. Each
press scrolls
the data 10
readings.
Press to scroll
backwards
through the
data file. Each
press scrolls
the data 10
readings.