Operating Instructions PA-xxP
961-00035 rev11
23/42
The pulse 2 profile editor screen follows the format of the pulse 1 screen.
The setup procedure is the same as that for the first pulse.
Delay time.
This is the delay between two weld pulses. The time is set in milli-seconds,
from 1 to 999ms.
Enable/Disable Voltage limits Pulse 2.
Turns GREEN to indicate limits enabled/on.
Returns to the
pulse 1 screen.
Enable/Disable Energy limits Pulse 2. Turns
GREEN to indicate limits enabled/on.
Displays Current
Profile number
and name.
Delay time
between pulse 1
and 2 in milli -
seconds.
Minimum and
Maximum voltage
limits.
Minimum and
maximum
energy limits.