Operating Instructions PA-xxP
961-00035 rev11
17/42
4
Setup (Man mode)
4.1
Setup screen
The setup profile screen shows the currently selected profile for that particular output.
From this screen, it is possible to edit the profile data, save or load profile, trigger a test
weld, setup limits (both voltage and energy) or enter the monitor menu to view further
information about this output.
Profile time.
There are three areas to a weld pulse, the upslope, peak and downslope
times.
To enter data, touch the appropriate field you wish to
change.
A numeric keypad pops-up, as shown opposite.
This shows the current value, and the minimum and
maximum values permited.
Use the number keys to enter the appropriate value.
CANCEL – exits keypad without changing value.
CLR – erases current value.
ENT – enters current value, and closes keypad.
BS – deletes character to the left of cursor.
DEL – deletes character under cursor.
<> - move cursor left and right.
Profile Current
. The is labelled LEVEL (Amps). The data range is depends upon the
model. Data entry is carried out the same way as for profile time.
Voltage/Energy Limits.
These fields can only be edited if they are turned on by pressing
the appropriate button at the top of the screen. Data entry is carried out in the same way
as for profile time.
Enable/Disable Energy limits Pulse 1. Turns
GREEN to indicate limits enabled/on.
Weld button. Press to fire weld on
this output, or STOP to terminate
Enable/Disable Voltage limits Pulse 1.
Turns GREEN to indicate limits enabled/on.
Displays Current
Profile number
And name.
Turns RED on a
fault, press for
information.
Minimum and
Maximum voltage
measured during
peak period.
Measured
energy of
weld pulse.
Single/Double Pulse
Mode.
Display Weld Monitor
Press to load or save
profiles.
Exit returns to
main monitor
display.