MN-35947
•
Rev 15
•
01/18
•
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
•
53
Installation
A union is required. Install a 1-1/2-inch (40mm) diameter connection, drain line and clamp into place. The drain
line must always be a positive gradient away from the Combitherm oven. An end of drain run air gap may be
required by local code. Vertical air vent required.
NOTICE:
In the U.S.A., this equipment is to be installed to comply with the Basic Plumbing Code of the Building
Officials and Code Administrators International, Inc. [BOCA], and the Food Service Sanitation Manual of
the Food & drug Administration [FdA].
1-1/2" (40mm) diameter CPVC
Tee Fitting Drain Connection
Drain vent pipe must be above
oven exhaust vent opening!
45 Degree Elbow
45 Degree Elbow
If a drain run exceeds 6' (1829mm)
to the floor sink, an air gap is
strongly recommended.
Use only glue designed for CPVC.
Oven exhaust vent opening
WATER DRAINAgE – fOR SINgLE OVEN