WeiGHt
SHiP DimenSionS
Pan CaPaCitY
NET
905 lbs est
411 kg
(L x W x H) 56" x 45" x 87"*
FULL–SIZE:
20" x 12" x 2-1/2"
Twenty (20)
PRODUCT MAXIMUM: 240 lb (109 kg)
SHIP
1175 lbs*
533 kg*
(1422 x 1143 x 2210mm)*
GN 1/1:
530 x 325 x 65mm
Twenty (20)
VOLUME MAXIMUM: 150 quarts (190 liters)
*DOMESTIC GROUND SHIPPING INFORMATION. CONTACT FACTORY
FOR EXPORT WEIGHT AND DIMENSIONS.
**HALF–SIZE SHEET:
18" x 13" x 1"
Twenty (20)
**ON WIRE SHELVES ONLY. ADDITIONAL WIRE
SHELVES REQUIRED FOR MAXIMUM CAPACITY.
eleCtriCal - CtC20-10G
(DeDiCateD CirCuit reQuireD)
VOLTAGE
PH
HZ
AWG (mm
2
)
CONNECTION
AMPS
BREAKER
kW
✑
✎
▲
120
1
60
12 (3.31)
L1, L2/N, G - no cord, no plug
13.0
20
1.7
✑
✒
▲
208 – 240
3
50/60
14 (2.08)
L1, L2, L3, G - no cord, no plug
9.6 – 8.4
15
2.0
✒
380 – 415
3
50/60
14 (2.08)
L1, L2, L3, N, G - no cord, no plug
9.2 – 8.4
15
2.0
✑
NORTH AMERICA VOLTAGE CHOICE
✎
GROUND FAULT OR RESIDUAL CURRENT PROTECTION DEVICE MUST ACCOMMODATE A LEAKAGE CURRENT OF
20mA
✒
INTERNATIONAL VOLTAGE CHOICE
▲
PER UL REQUIREMENTS, MUST BE PERMANENTLY CONNECTED TO ELECTRICAL SUPPLY SOURCE
ul marked
appliances
maximum
input
btu/h
minimum
input
btu/h
maximum inlet
Pressure
inches WC
minimum inlet
Pressure
inches WC
maximum fuel Consumption*
aGa marked
appliances
maximum
input
mJ/h
minimum
input
mJ/h
maximum inlet
Pressure
kPa
minimum inlet
Pressure
kPa
maximum fuel
Consumption
CfH
GPH
m
3
/h
l/h
Natural Gas
140,000
107,000
14.0
5.5
133.3
N/A
Natural Gas
147.7
112.9
3.48
1.13
3.9
N/A
Propane
9.0
56.0
1.5
Propane
2.75
1.5
5.8
*Assumes an average heating value for natural gas to be 1050 BTU/SCF and a specifc gravity of 0.60.
The assumed value for propane gas is 2,500 BTU/SCF, and a specific gravity of 1.53
Ce marked
appliances
maximum input
minimum input
nominal Gas Pressure
mbar
maximum Gas Pressure
mbar
maximum fuel Consumption
m
3
kWh (Hs)
kWh (Hi)
kWh (Hs)
kWh (Hi)
2E (G20)
41.1
37.0
31.4
28.3
20
50
3.9
2LL (G25)
20
4.6
3P (G31)
40.2
37.0
31.4
28.9
37
1.5
3B/P (G30)
29
1.5
GaS reQuirementS
(GaS tYPe muSt be SPeCifieD on orDer)
HOOK-UP: 3/4" NPT
Water reQuirementS
Water QualitY StanDarDS
tWo (2) ColD Water inletS - DrinKinG QualitY*
one (1) treateD Water inlet: 3/4" NPT connection. Line pressure 30 psi minimum dynamic and
90 psi maximum static (200 to 600 kPa) at a minimum flow rate of 0.80 gpm (3 L/min).
one (1) untreateD Water inlet: 3/4" NPT connection. Line pressure 30 psi minimum dynamic and
90 psi maximum static (200 to 600 kPa) at a minimum flow rate of 2.64 gpm (10 L/min).
* Both inlets can be from same source. Divide using a manifold. Run one side through treatment device before running to oven.
Must meet line pressure and flow rate specifications for both inlets.
Water Drain: 1-1/2" (40mm) connection with a vertical vent to extend above the exhaust vent.
materials must withstand temperatures up to 200°F (93°C).
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and
if required, a means of “water treatment” provided that would meet
compliance requirements with the published water quality standards shown
below. Non-compliance with these minimum standards will potentially
damage this equipment and/or components and void the original equipment
manufacturer’s warranty. Alto-Shaam recommends using OptiPure
®
[www.
optipurewater.com] products to properly treat your water.
Contaminant
Free Chlorine
Hardness
Chloride
pH
Silica
Total Dissolved Solids (tds)
inlet Water requirements
Less than 0.1 ppm (mg/L)
30-70 ppm
Less than 30 ppm (mg/L)
7.0 to 8.5
Less than 12 ppm (mg/L)
Treated line: 50-125 ppm
Untreated line: 50-360 ppm
ClearanCe reQuirementS
left:
0" (0mm)
18" (457mm) recommended service access
riGHt:
0" (0mm) Non-combustible surfaces
2" (51mm) door swing or combustible surfaces
toP:
20" (508mm) for air movement
bottom:
5-1/8” (130mm) for legs, air aintake
baCK:
4" (102mm)
4-5/16” (109mm) optional plumbing kit
inStallation reQuirementS
• Oven must be installed level.
• Hood installation is required.
• Water supply shut-off valve and back-flow preventer when required by local code.
DimenSionS: H x W x D
eXterior: 79-1/4" x 35-11/16" x 42-1/4" (2012mm x 906mm x 1072mm)
eXterior WitH reCeSSeD Door:
79-1/4" x 40-11/16" x 42-1/4" (2012mm x 1033mm x 1072mm)
interior: 60-7/16" x 16-1/4" x 28-1/16" (1535mm x 411mm x 712mm)
B
A
E
D
B
D
A
E
C
114 мм
108 мм
202 мм
39-11/16" (1008mm)
42-1/4" (1072mm)
28-13/16" (732mm)
1-15/16" (49mm)
1" (24mm)
79-1/4
" (2012mm)
60-13/16
" (1545mm)
35-11/16" (906mm)
1-11/16" (42mm)
59-1/4
" (1504mm)
33-13/16
" (858mm)
11-13/16
" (299mm)
9-3/16
" (233mm)
3-1/4" (81mm)
4-3/16"
(106mm)
4-1/8" (105mm)
5" (126mm)
33-13/16" (858mm)
1" (24mm)
CTC20-10G
GAS BOILER-FREE
A= UNTREATED WATER
B= TREATED WATER
C= ELECTRICAL (BOTTOM)
D= GAS
E= WATER DRAIN