MN-35947
•
Rev 15
•
01/18
•
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
•
59
Installation
Grease Collection Hose
A
F
On/Off Ball Valve
Container
Fill Cap
Grease
Collection
Container
Vent
Cap
Recommended
Capacity
G
Thumb
screw
Hose guide
bracket
Hose hanger bracket with film
Hose hanger bracket
C
D
E
B
•
Grease Collection Hose Assembly is attached to the oven in
the back.
•
The hose guide bracket can be attached on either the left
side or the right side toward the back. Placement on the
left side is recommended whenever possible.
Thumb
screws are in position for this purpose. Remove thumb
screws, position hose guide bracket and secure screws
(
PHoto
a
). Thread grease hose through the guide.
•
The hose hanger bracket can be attached on either the
left side or the right side toward the front of the oven.
Placement on the left side is recommended whenever
possible.
Remove the plastic protective fi lm from the
bracket (
PHoto
b
,
c
). Pan head screws are in position beneath
the oven for this purpose. For stacked confi gurations,
always place the hanger bracket on bottom of the top
oven.
Remove pan head screws and washers (
PHoto
d
),
position hose hanger bracket on either side of the oven and
secure screws and washers (
PHoto
e
,
f
). The hanger bracket
is used to secure the grease collection hose while changing
grease collection containers.
•
Place Grease Collection Containers inside the tray of the
Mobile Grease Collection Cart. Roll into place next to the
oven and apply the caster brake.
•
Loosen vent cap on container.
Pull out the Grease
Collection Hose Assembly from the back of the unit.
Remove collection container fi ll cap (
PHoto
g
).
•
Screw Grease Collection Hose Assembly on to collection
container until snug.
•
Turn ball valve handle to the ON position.
❖
gREASE COLLECTION INSTALLATION (If EQuIppED WITH THIS OpTION)