eleCtriCal - CtP10-10G
(DeDiCateD CirCuit reQuireD)
WITH COMBISMOKER
®
OPTION
VOLTAGE
PH
HZ
AWG (mm
2
)
CONNECTION
no cord, no plug
AMPS
BREAKER
kW
CONNECTION
no cord, no plug
AMPS
BREAKER
kW
✑ ✎ ▲
120
1
60
12 (3.31)
L1, L2/N, G
6.8
20
.84
L1, L2/N, G
12.0
20
1.5
✑ ✒ ▲
208 – 240
1
✝
50/60
14 (2.08)
L1, L2/N, G
4.8 – 4.2
15
1.0
L1, L2/N, G
7.3 – 7.1
15
1.5 – 1.7
✑ ✒ ▲
208 – 240
3
50/60
14 (2.08)
L1, L2, L3, G
4.8 – 4.2
15
1.0
L1, L2, L3, G
7.3 – 7.1
15
1.5 – 1.7
✒
380 – 415
3
50/60
14 (2.08)
L1, L2, L3, N, G
4.6 – 4.2
15
1.0
L1, L2, L3, N, G
7.2 – 7.1
15
1.6 – 1.7
NORTH AMERICA VOLTAGE CHOICE
✎
GROUND FAULT OR RESIDUAL CURRENT PROTECTION DEVICE MUST ACCOMMODATE A LEAKAGE CURRENT OF
20mA
✒
INTERNATIONAL VOLTAGE CHOICE
✝
ELECTRICAL SERVICE CHARGE APPLIES
▲
PER UL REQUIREMENTS, MUST BE PERMANENTLY CONNECTED TO ELECTRICAL SUPPLY SOURCE
WeiGHt
Pan CaPaCitY
STANDARD MODEL
WITH COMBISMOKER
®
OPTION
NET
625 lbs EST (283 kg)
FULL–SIZE:
20" x 12" x 2-1/2"
GN 1/1:
530 x 325 x 65mm
**HALF–SIZE SHEET: 18" x 13" x 1"
Eleven (11)
Eleven (11)
Eleven (11)
Ten (10)
Ten (10)
Eleven (11)
SHIP
695 lbs* (315 kg*)
SHiP DimenSionS
ProDuCt CaPaCitY
(L x W x H) 56" x 45" x 65"*
PRODUCT MAXIMUM
120 lb (54 kg)
(1422mm x 1143mm x 1651mm)*
VOLUME MAXIMUM
75 quarts (95 liters)
*DOMESTIC GROUND SHIPPING INFORMATION. CONTACT FACTORY FOR EXPORT WEIGHT AND DIMENSIONS.
ul marked
appliances
maximum
input
btu/h
minimum
input
btu/h
maximum inlet
Pressure
inches WC
minimum inlet
Pressure
inches WC
maximum fuel
Consumption*
aGa marked
appliances
maximum
input
mJ/h
minimum
input
mJ/h
maximum inlet
Pressure
kPa
minimum inlet
Pressure
kPa
maximum fuel
Consumption
CfH
GPH
m
3
/h
l/h
Natural Gas
80,000
53,000
14.0
5.5
76.2
N/A
Natural Gas
84.4
55.9
3.48
1.13
2.2
N/A
Propane
9.0
32.0
0.9
Propane
2.75
0.9
3.3
*Assumes an average heating value for natural gas to be 1050 BTU/SCF and a specifc gravity
of 0.60. The assumed value for propane gas is 2,500 BTU/SCF, and a specific gravity of 1.53
Ce marked
appliances
maximum input
minimum input
nominal Gas Pressure
mbar
maximum Gas Pressure
mbar
maximum fuel Consumption
m
3
kWh (Hs)
kWh (Hi)
kWh (Hs)
kWh (Hi)
2E (G20)
23.3
21.0
15.5
14.0
20
50
2.2
2LL (G25)
20
2.6
3P (G31)
22.8
21.0
15.5
14.3
37
0.9
3B/P (G30)
29
0.9
GaS reQuirementS
(GaS tYPe muSt be SPeCifieD on orDer)
HOOK-UP: 3/4" NPT
Water reQuirementS
Water QualitY StanDarDS
tWo (2) ColD Water inletS - DrinKinG QualitY*
one (1) treateD Water inlet: 3/4" NPT connection. Line pressure 30 psi minimum dynamic and
90 psi maximum static (200 to 600 kPa) at a minimum flow rate of 0.26 gpm (1 L/min).
one (1) untreateD Water inlet: 3/4" NPT connection. Line pressure 30 psi minimum dynamic and
90 psi maximum static (200 to 600 kPa) at a minimum flow rate of 2.64 gpm (10 L/min).
* Both inlets can be from same source. Divide using a manifold. Run one side through treatment device before running to oven.
Must meet line pressure and flow rate specifications for both inlets.
Water Drain: 1-1/2" (40mm) connection with a vertical vent to extend above the exhaust vent.
materials must withstand temperatures up to 200°F (93°C).
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and
if required, a means of “water treatment” provided that would meet
compliance requirements with the published water quality standards shown
below. Non-compliance with these minimum standards will potentially
damage this equipment and/or components and void the original equipment
manufacturer’s warranty. Alto-Shaam recommends using OptiPure
®
[www.
optipurewater.com] products to properly treat your water.
Contaminant
Free Chlorine
Hardness
Chloride
pH
Silica
Total Dissolved Solids (tds)
inlet Water requirements
Less than 0.1 ppm (mg/L)
30-70 ppm
Less than 30 ppm (mg/L)
7.0 to 8.5
Less than 12 ppm (mg/L)
Treated line: 50-125 ppm
Untreated line: 50-360 ppm
ClearanCe reQuirementS
left:
0" (0mm)
18" (457mm) recommended service access
riGHt:
0" (0mm) Non-combustible surfaces
2" (51mm) door swing or combustible surfaces
toP:
20" (508mm) for air movement
bottom:
5-1/8” (130mm) for legs, air aintake
baCK:
4" (102mm)
4-5/16” (109mm) optional plumbing kit
inStallation reQuirementS
• Oven must be installed level.
• Hood installation is required.
• Water supply shut-off valve and back-flow preventer when required by local code.
DimenSionS: H x W x D
eXterior:
45-11/16" x 35-11/16" x 41-7/16" (1160mm x 906mm x 1053mm)
eXterior WitH reCeSSeD Door:
45-11/16" x 40-11/16" x 41-7/16" (1160mm x 1033mm x 1053mm)
interior:
31-1/2" x 16-1/4" x 28-1/16" (800mm x 411mm x 712mm)
CTP10-10G
GAS BOILER-FREE
WMTS 104
WM 40202
Global-Mark.com.au
A = Treated water
B = Untreated water
C = Gas
D = Electrical (Back)
E = Water Drain
F = Electrical (Bottom)
Front
Back
Top/Bottom