MN-35947
•
Rev 15
•
01/18
•
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
•
71
Inspection Checklist
12-month inspection Checklist
g
Inspect - The heat exchanger for any signs of major deformation. If yes,
immediately
remove from service and take corrective
action steps.
g
Inspect - The heat exchanger for any loose/disconnected pipes or flanges. If yes,
immediately
remove from service and take
corrective action steps.
g
Inspect and Ensure - Exhaust pipes are exiting the oven cavity
g
Inspect - Heat exchanger flange gasket (replace as needed)
g
Inspect and Tighten - Heat exchanger flange bolts
g
Inspect and Tighten - Heat exchanger burner flange hardware & gasket (replace as needed)
g
Inspect and Tighten - Heat exchanger igniter flange hardware & gasket (replace as needed)
g
Inspect - Heat exchanger exhaust pipes (ensure they are exiting out past the oven cavity ceiling flange) - ESG models only
g
Inspect - Oven cavity ceiling flange & flange gasket - ESG models only
g
Tighten - Burner flange bolts
g
Tighten - Igniter flange bolts
Inspect - Heat exchanger weep holes to ensure they are free of obstructions (if the hole is obstructed, immediately remove oven
from service and replace the heat exchanger) - Not applicable to CTP/CTC models
E
Inspect - Convection elements for signs of cracking, deformation, or damage
Replace - Oven lamp cover(s) & gasket(s)
Descale the oven interior
Inspect - Upper and lower door hinges and pins
Inspect - Door gasket (replace as needed)
Inspect - Door upper and lower hinges (replace as needed)
Wipe the inner door glass
Inspect - Front drip tray (clean as needed)
Inspect - Front drip tray hose
Inspect - Control overlay
Inspect and Tighten - All electrical connections
Inspect and Tighten - All cooling fans for proper operation
EB
Electric boiler units only
E
g
Gas units only
Electric units only
unit information
business name: _______________________________________
model number: _______________________________________
Serial number: ______________________________
12-month inspection Start Date: ______________________________