24
•
MN-35947
•
Rev 15
•
01/18
•
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
#436 - 01/18
DUE TO ONGOING PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
WWW.ALTO-SHAAM.COM
ul marked
appliances
maximum
input
btu/h
minimum
input
btu/h
maximum inlet
Pressure
inches WC
minimum inlet
Pressure
inches WC
maximum fuel
Consumption*
aGa marked
appliances
maximum
input
mJ/h
minimum
input
mJ/h
maximum inlet
Pressure
kPa
minimum inlet
Pressure
kPa
maximum fuel
Consumption
CfH
GPH
m
3
/h
lPH
Natural Gas
266,000
177,000
14.0
5.5
253.3
N/A
Natural Gas
280.6
186.7
3.48
1.13
7.4
N/A
Propane
9.0
106.4
2.9
Propane
2.75
2.9
11.1
*Assumes an average heating value for natural gas to be 1050 BTU/SCF and a specifc gravity
of 0.60. The assumed value for propane gas is 2,500 BTU/SCF, and a specific gravity of 1.53
Ce marked
appliances
maximum input
minimum input
nominal Gas Pressure
mbar
maximum Gas Pressure
mbar
maximum fuel Consumption
m
3
kWh (Hs)
kWh (Hi)
kWh (Hs)
kWh (Hi)
2E (G20)
80.0
72.0
56.0
50.4
20
50
7.6
2LL (G25)
20
8.9
3P (G31)
78.3
72.0
54.6
50.4
37
2.9
3B/P (G30)
29
2.9
GaS reQuirementS
(GaS tYPe muSt be SPeCifieD on orDer)
HOOK-UP: 3/4" NPT
eleCtriCal - CtP20-20G
(DeDiCateD CirCuit reQuireD)
WITH COMBISMOKER
®
OPTION
VOLTAGE
PH
HZ
AWG (mm
2
)
CONNECTION
no cord, no plug
AMPS
BREAKER
kW
CONNECTION
no cord, no plug
AMPS
BREAKER
kW
✑
✎
▲
120
1
60
12 (3.31)
L1, L2/N, G
13.6
20
1.7
L1, L2/N, G
18.4
25
2.3
✑
✒
▲
208 – 240
1
✝
50/60
14 (2.08)
L1, L2/N, G
9.6 – 8.4
15
2.0
L1, L2/N, G
12.1 – 11.3
15
2.5 – 2.7
✑
✒
▲
208 – 240
3
50/60
14 (2.08)
L1, L2, L3, G
9.6 – 8.4
15
2.0
L1, L2, L3, G
12.1 – 11.3
15
2.5 – 2.7
✒
380 – 415
3
50/60
14 (2.08)
L1, L2, L3, N, G
9.2 – 8.4
15
2.0
L1, L2, L3, N, G
11.8 – 11.3
15
2.6 – 2.7
✑
NORTH AMERICA VOLTAGE CHOICE
✎
GROUND FAULT OR RESIDUAL CURRENT PROTECTION DEVICE MUST ACCOMMODATE A LEAKAGE CURRENT OF
20mA
✒
INTERNATIONAL VOLTAGE
CHOICE
▲
PER UL REQUIREMENTS, MUST BE PERMANENTLY CONNECTED TO ELECTRICAL SUPPLY SOURCE
WeiGHt
SHiP DimenSionS
Pan CaPaCitY
NET
1100 lbs (499 kg) est
Recessed Door: 1217 lbs (552 kg) est
(L x W x H) 53" x 53" x 87"*
(1346 x 1346 x 2210mm)*
FULL–SIZE: 20" x 12" x 2-1/2"
Forty (40)
GN 1/1: 530 x 325 x 65mm
Forty (40)
GN 2/1: 650 x 530 x 65mm
Twenty (20)
**FULL–SIZE SHEET:
18" x 26" x 1"
Twenty (20)
PRODUCT MAXIMUM: 480 lb (218 kg)
VOLUME MAXIMUM: 300 quarts (380 liters)
**ON WIRE SHELVES ONLY. ADDITIONAL WIRE
SHELVES REQUIRED FOR MAXIMUM CAPACITY.
SHIP
1250 lbs* (567 kg*)
Recessed Door: 1350 lbs* (612 kg)*
*DOMESTIC GROUND SHIPPING INFORMATION. CONTACT FACTORY FOR EXPORT WEIGHT
AND DIMENSIONS.
Water reQuirementS
Water QualitY StanDarDS
tWo (2) ColD Water inletS - DrinKinG QualitY*
one (1) treateD Water inlet: 3/4" NPT connection. Line pressure 30 psi minimum dynamic and
90 psi maximum static (200 to 600 kPa) at a minimum flow rate of 0.80 gpm (3 L/min).
one (1) untreateD Water inlet: 3/4" NPT connection. Line pressure 30 psi minimum dynamic and
90 psi maximum static (200 to 600 kPa) at a minimum flow rate of 2.64 gpm (10 L/min).
* Both inlets can be from same source. Divide using a manifold. Run one side through treatment device before running to oven.
Must meet line pressure and flow rate specifications for both inlets.
Water Drain: 1-1/2" (40mm) connection with a vertical vent to extend above the exhaust vent.
materials must withstand temperatures up to 200°F (93°C).
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and
if required, a means of “water treatment” provided that would meet
compliance requirements with the published water quality standards shown
below. Non-compliance with these minimum standards will potentially
damage this equipment and/or components and void the original equipment
manufacturer’s warranty. Alto-Shaam recommends using OptiPure
®
[www.
optipurewater.com] products to properly treat your water.
Contaminant
Free Chlorine
Hardness
Chloride
pH
Silica
Total Dissolved Solids (tds)
inlet Water requirements
Less than 0.1 ppm (mg/L)
30-70 ppm
Less than 30 ppm (mg/L)
7.0 to 8.5
Less than 12 ppm (mg/L)
Treated line: 50-125 ppm
Untreated line: 50-360 ppm
ClearanCe reQuirementS
left:
0" (0mm)
18" (457mm) recommended service access
riGHt:
0" (0mm) Non-combustible surfaces
2" (51mm) door swing or combustible surfaces
toP:
20" (508mm) for air movement
bottom:
5-1/8” (130mm) for legs, air aintake
baCK:
4" (102mm)
4-5/16” (109mm) optional plumbing kit
inStallation reQuirementS
• Oven must be installed level.
• Hood installation is required.
• Water supply shut-off valve and back-flow preventer when required by local code.
DimenSionS: H x W x D
eXterior:
79-1/4" x 43-3/4" x 47" (2012mm x 1111mm x 1192mm)
eXterior WitH reCeSSeD Door:
79-1/4" x 48-3/4" x 47" (2012mm x 1238mm x 1192mm)
interior:
60-7/16" x 24-1/4" x 32-3/4" (1535mm x 616mm x 832mm)
CTP20-20G
GAS BOILER-FREE
C (at bottom of oven)
47-7/8" (1215mm)
47" (1192mm)
43-3/4" (1111mm)
B
A
E
33-9/16" (852mm)
1-15/16" (49mm)
41-7/8" (1063mm)
1" (24mm)
79-1/4" (2012mm)
4-1/2
" (1
14mm)
4-1/4" (108mm)
7-15/16" (202mm)
D
59-1/4
" (1504mm)
33-13/16
" (858mm)
11-13/16
" (299mm)
9-3/16
" (233mm)
B
D
A
E
3-1/4" (81mm)
4-3/16"
(106mm)
4-1/8" (105mm)
5" (126mm)
1-11/16" (42mm)
73-5/8" (1869mm)
A= UNTREATED WATER
B= TREATED WATER
C= ELECTRICAL
D= GAS
E= WATER DRAIN
WMTS 104
WM 40202