Combitherm® CT PROformance™ and CT Classic Series Installation Manual
Installation
GND
PE
A
A
B
1
2
1
2
3
B
1
* For 1-phase appliances remove red wire and orange wire.
* For 3-phase appliances remove white wire.
* For 1-phase appliances remove red wire and orange wire.
* For 3-phase appliances remove white wire.
2*
3
4
5
1
B
2
B
1
2*
1
3
4
5
GR
L1 L2/N
GND
BK WH GR
BK RD WH
BK RD OR GR
L1
208-240V
3Ph
120V
1Ph
380-415V
3Ph
208-240V
1Ph
L2/N
GND
BK
WH
GR
1/2"
(12mm)
Note:
Note:
Cabling and
connectors must be supplied
for 120V configurations.
Illustrations are representative only. Your appliance may vary.
Strip the wires, then connect them to the terminal strip.
Remove enough cable covering so that wires reach the terminal strip.
L1
L2 L3
2
4
6
Position and attach the support plate
(x)
.
Discard the cover plate if applicable.
Depending on the application, install the straight or elbow fitting to the cable.
3
x
x
x
Applications
for the
Americas
Cut threads into nut before installing fitting.To do so, apply a
light lubricant and thread nut on and off fitting.
Cut threads into nut before installing fitting.To do so, apply a
light lubricant and thread nut on and off fitting.
Power supply side
Appliance side
Install the fitting/wiring to the appliance.
1-1/2" NPT and smaller bushings through the
bottom, all others through the back.
Installation point for
1-1/2” NPT and
smaller 90º bushings.
5
Route the wires.
Keep wires away from hot surfaces such as water tank,
drain pipe, motor, edges of sheet metal, vent pipes, or other appliances.
ELECTRICAL KIT INSTALLATION – 60 Hz