![Alpha ALPHA6000 Series Manual Download Page 77](http://html1.mh-extra.com/html/alpha/alpha6000-series/alpha6000-series_manual_2905270077.webp)
Chapter 4 Parameter Index
http://www.acdrive-china.com
77
This page only for 35R5GB/37R5PB and over
Function
code
Function
Name
LCD
Display
Range of settings
Default
Change
MODBUS
Address
P3.05
Multi-fu
nction
input
selection
Terminal
X5
Termin
al X5
functio
n
27 ×
0405
P3.06
Multi-fu
nction
input
selection
Terminal
X6
Termin
al X6
functio
n
43: Pause the PLC
operating
44: Reset PLC stop
status
45: Start Wobble
frequency operating
25~45: Ibid
46: Reset the Wobble
frequency operating
status
47: Start PID operation
48:Reserved
49: Timing drive input
50: Counter trig signal
input
51: Counter clear
52: Actual Length clear
53: Timing units chose
28 ×
0406
P3.07
Multi-fu
nction
input
selection
Terminal
X7
Termin
al X7
functio
n
0 ×
0407
P3.08
Multi-fu
nction
input
selection
Terminal
X8
Termin
al X8
functio
n
0
~
53: Ibid
54: PUL: Pulse input
( If have 2 signals
input, follow X7)
55: Single-phase speed
measuring input ( If
have 2 signals
input, follow X7)
56: Speed measuring
input SM1(only for
X7)
57: Speed measuring
input SM2(only for
X8)
0 ×
0408