Chapter 2 Installation and Wiring
http://www.acdrive-china.com
32
●
Wire Multi-function Output Terminals
1
)
Multi-function output terminals D0 as switching output can use the internal 24V
power supply of ac drive and the wiring method is shown in Figure 2-25.
Fig 2-25 Wiring method 1 of DO as switching output
2
)
Multi-function output terminals D0 as switching output can also use the external 9
~
30V power supply and the wiring method is shown in Figure 2-26.
Fig 2-26 Wiring method 2 of DO as switching output
DC 9
~
30V
COM
DO
24V
5V
+24V
+ -
relay
R