PC.22
Linear speed
display
coefficient
Line speed
display
coefficient
0.1
~
999.9%
Linear speed =
Running
frequency ×PC.22
(no PG))
Linear speed =
Rotate
speed×PC.22
(PG)
Reference linear
speed = reference
frequency* PC.22
(no PG)
Reference linear
speed=reference
speed×PC.22
(PG)
Note: This setting
has no influence
to actual speed
100.0
%
○
0D16
Pd: Protection and Fault Parameters
Function
code
Function
Name
LCD
Display
Range of
settings
Default
Change
MODBUS
Address
Pd.00
Motor above
load
protection
mode
selection
Overload
protection
selection
0:Disabled
1:Common
motor (with
low speed
compensation
)
2:Variable
frequency
motor
(without low
speed
compensation
)
1
× 0E00
Pd.01
Electro
thermal
protective
value
Electro
thermal
protective
value
20
~
110%
100%
○