![Alpha ALPHA6000 Series Manual Download Page 71](http://html1.mh-extra.com/html/alpha/alpha6000-series/alpha6000-series_manual_2905270071.webp)
Chapter 4 Parameter Index
http://www.acdrive-china.com
71
This page only for 3004GB and below
Function
code
Function
Name
LCD
Display
Range of settings
Default
Change
MODBUS
Address
P3.01
Multi-fun
ction
input
selection
Terminal
X1
Terminal
X1
function
0: NULL, No defined
1: FWD: Running
Forward
2: REV: Running
Reverse
3: RUN
4: F/R running
direction
5: HLD self-hold
selection
6: RST reset
7: FC Setting
frequency selection
8: FJOG(JOG FWD)
9: RJOG(JOG REV)
10: UP
11:DOWN
12: UP/DOWN Reset
13: FRE
Coast-to-stop
14: Forced outage
(According to Dec
time4) 15: DC
injection braking
16: Acc/Dec prohibit
17: Ac drive running
prohibit
18: S1 Multi-step
Speed 1
19: S2 Multi-step
Speed 2
20: S3 Multi-step
Speed 3
21: S4 Multi-step
1 ×
0401