Chapter 5 Parameter Introductions
http://www.acdrive-china.com
136
Table 5-3-2 Multi-step frequency
Frequency selection
Description
SS3 SS2 SS1
Frequency
setting
OFF OFF ON
Multi-step
frequency 1
OFF
ON OFF
Multi-step
frequency 2
OFF
ON ON
Multi-step
frequency 3
ON
OFF
OFF
Multi-step
frequency 4
ON
OFF
ON
Multi-step
frequency 5
ON ON OFF
Multi-step
frequency 6
ON ON ON
Multi-step
frequency 7
OFF OFF OFF
Common
Operating
SS3
ON
ON
ON
ON
ON
ON
ON
ON
SS2
SS1
Operation Freq.(Hz)
Time
P2.12
P2.13
P2.15
P2.17
P2.14
P2.12
P2.16
P2.11
For models power above or equal to 35R5GB/37R5PB, at least three terminals of the
eight are defined as SS1, SS2 and SS3
,
This function can be active. If the definition of
terminal and the function is less one, the combination will be invalid. The function can
be defined repeatedly. If one of the repeat terminals is valid, the combination function
will valid.
If it has defined S1~S7 and SS1~SS3 function at the same time, S1~S7 is prior.
25: Command channel switch to Terminal control 2
◆
Switch the run command mode to “Terminal control 2”, if this function terminal is
enabled.
29: Command channel switch to Keyboard control:
◆
Switch the run command mode to “Keyboard control”, if this function terminal is
enabled.
30
~
35: Acc/Dec time