Main displays the inverter working status
and information, including:
• Power: Current PV power
• Total: Total power generation.
• Battery: Current remaining battery
power (SOC).
• Normal: Current working state of the
equipment, including Standby.
In the Main interface, press ENT key to
enter the menu’s main interface.
Use the up and down key to select a
sub-menu, press the ENT key to enter the
selected sub-menu, press Return key to
return to the previous layer.
Status menu contains five sub-menus:
Solar, Battery, Grid, UPS and Comm .These
display the relevant information about the
current physical or communication
interface respectively.
Grid interface displays the real-time
information on the utility grid side:
voltage U, current I, frequency F, P
Inv
,
P
MeterAC
, P
MeterDC
.
Solar interface displays the real-time
information of PV side: voltage U1, current
I1, power P1, voltage U2, current I2 and
power P2.
4.2.1 Main
4.2.2 Status
4.2.3 History
Battery interface displays the real-time
information of battery side: voltage U,
current I, power P, residual capacity of
Battery (SOC), the internal environmental
temperature Temp.
UPS interface displays the real-time
information in this mode: voltage U,
current I, power P, frequency F
Communication interface displays the
real-time communication situation of
BMS, Net, MeterGrid and MeterDC.
History menu contains seven sub-menus:
Grid Consumption, INV Gen., BAT Gen., PV
Gen., Grid Charge, PV Charge, Error Logs
Grid Consumption interface displays today’s
or total load consumption from grid
> > > > > MENU < < < < <
>Status
History
Setting
> > > > Status < < < <
>Grid
Solar
Battery
> > > > > Grid < < < < <
>
U 230.2V
I 2.0A
F 49.99Hz
> > > > > Solar < < < < <
>
U1 360.0V
I1 1.0A
P1 360W
> > > Battery < < <
>
U 48.0V
I 10.0A
P 480W
> > > > > UPS < < < < <
>
U 230.2V
I 2.0A
P 460W
> > > > History < < <
>
Grid Consump
INV Gen.
BAT Gen.
> Grid Consump <
>
Today:
20.8kWh
EMS INTRODUCTION AND SET UP
EMS INTRODUCTION AND SET UP
36
37
Power 0W
Total 00.0kWh
Battery %
Normal
> > > > > Comm < < < < <
> BMS Yes
Net Yes
MeterGrid Yes