Step 5
Click the Battery Function and
check battery type SMILE5-BAT.
Step 7
Check the Battery Ready
function set No. If you only use the
inverter without battery, please set it
Yes.
Step 8
Click the Grid Function to set
up relevant parameters of the grid
Step 6
Check SOC Calibration
function set No.
Step 9
Set the Max. Feed in rate value.
Step 10
Click Function-System
Mode to set system mode: DC, AC,
Hybrid.
Step 11
Click the mode then set up
work mode.(self-use or force time
charge)
Step 12
If you want to use force
charge, sett Enable here.
Step 13
Set the charge and discharge
time.
Step 15
Click Safety in the setting
menu. Set safety standard.
AS4777 for Australia, ARN4105 for
Germany, CEI0_21 for Italy, G83_2 for
Great Britain, NRS097_2_1 for South
Africa, RD1699 for Spain, VDE0216 for
60Hz countries.
Step 16
If you use CT meter, please
set CT meter enable and the relevant
ratio.
Step 14
Set the UPS Reserve SOC, it
means how much battery energy to
reserve for UPS function.
Step 17
If you use UPS function,
please set the mute as YES in UPS
System interface and the relevant
Frequency.
Step 18
Click System in the setting
menu. Click Date &Time and set up
the date and time.
Step 17
Click Ethernet to set the IP
address. DHCP mode means that setup
IP address is set up automatically.
If you want to set up the IP address
manually, please choose manual mode.
> > > Battery < < < <
>
Bat Model
Smile5-BAT
> > > Battery < < < <
>
SOC Calibration
No
> > > Battery < < < <
>
Battery Ready
No
> > > > > Grid < < < < <
>
FeedIN Control
Power Limit
Power Factor
Max. Feed in rate
>
User Value:
50%
> > System Mode < <
>
DC
AC
Hybrid
> > > Work Mode < <
>
Force Charge
Enable
> > > Work Mode < <
>
Force Charge
Enable
> > > Work Mode < <
>
Charge
Start Time 1
01
:
00
> > > Work Mode < <
>
UPS Reserve SOC
11 %
> > > > Safety < < < <
>
Country
AS4777
> > > CT Meter < < <
>
Enable OFF
Ratio
1
> > > Date&Time < <
>
2018 - 02 - 02
09 : 46
> > UPS System < <
Frequency: 50Hz
>
Mute YES
> > > Ethernet < < <
IP method
>
DHCP
EMS INTRODUCTION AND SET UP
EMS INTRODUCTION AND SET UP
40
41