Allied Construction Products, LLC www.alliedcp.com
SOMM577202_14mar
22
7.0 Care And Maintenance – [cont’d]
WARNING
Escaping fluid under pressure can cause
injury from injection. Always relieve
pressure before disconnecting hydraulic
lines or other pressurized lines.
If any fluid appears to penetrate the skin, seek
immediate medical attention. Qualified technicians
with special tools and training should test the
hydraulic system.
IMPORTANT
Contamination can shorten service life. Prevent dirt
and debris from contaminating the oil. Always clean
the area around the connections prior to removal of
plugs or caps. Have a suitable container and rags on
hand before disconnecting hose. Collect fluid and
dispose of it properly.
7.11.2 How to Measure Oil Pressure
Fig. 7-8 Measuring Oil Pressure
Connect a pressure gauge [0-5000 PSI] into the
supply line near the breaker.
Start the carrier and allow the oil temperature to
reach its normal operating temperature before
starting.
Move the breaker into a suitable working position.
Set the engine rpm at the normal operating
speed
Set work mode to breaker.
Start the breaker and record the oil pressure. It's
normal for the needle of the gauge to pulsate.
Compare the average reading with the values
listed in the Technical Data Section of this
manual.
Make all necessary adjustments. Remove the
gauge when finished.
Summary of Contents for Hy-Ram HR270