6.0 Operation – [cont’d]
At temperatures below minus 4º F [-20º C], the
hydraulic oil must be warmed up before starting
the Breaker. Follow instructions provided by the
carrier manufacturer for on warming up the
carrier.
Keep oil circulating in the carrier during pauses in
work to prevent it from falling below a
temperature that is too cold for normal operation.
Specify hydraulic oils with viscosity suitable for
the climate conditions. In general, the hydraulic
oil that was originally specified for the machine by
the carrier manufacturer can be used with the
Allied equipment.
Use oil viscosity based on the expected air
temperature range during the period between oil
changes.
Optimum oil viscosity for the breaker @ operating
temperature is 60 – 30cSt. Allowable oil viscosity
range 1000 – 20cSt.
6.4.5 Flow Adjustment
Available on Hy-Ram models HR390 thru HR710.