Allied Construction Products, LLC www.alliedcp.com
SOMM577202_14mar
14
6.0 Operation – [cont’d]
6.4.2 Working Underground
When using the Breaker underground [tunneling or
mining applications] special safety regulations may
apply. Additional considerations include:
Use of water sprays to suppress dust.
Use of fire-resistant hydraulic fluids. Hydraulic
systems using fire-resistant fluids require special
engineering consideration when using the
Breaker. With some fluids, decreased flow and/or
pressure to the Breaker may be necessary.
6.4.3 Working in Hot Temperatures
IMPORTANT
Serious equipment damage may result if proper
procedures are not followed. Check the oil
temperature often to ensure it does not exceed
176ºF [80ºC]. If higher temperatures are
measured in the tank, refer to the
Troubleshooting Section in this manual.
Specify hydraulic oils with viscosity suitable for
the climate conditions. In general, the hydraulic
oil that was originally specified for the machine by
the carrier manufacturer can be used with this
equipment.
Check the oil level in reservoir
Inspect the cooling system. Good air circulation is
essential in dissipating heat from the hydraulic oil.
Make sure the cooler is clean.
6.4.4 Working in Cold Temperatures
IMPORTANT
Serious equipment damage may result if proper
procedures are not followed. When working in
temperature conditions below minus 4ºF [-20ºC],
operating the Breaker with cold hydraulic oil may
damage the seals.