Environmental conditions
mains voltage
:
220V (50-60 Hz/5 VA) -15% /+10%
temperature
use
:
-5˚C to +60˚C
storage
:
-20˚C to +70˚C
humidity
use
:
10% to 75% (non condensing)
storage
:
5% to 95% (non condensing)
dimensions
:
60x170x160mm (wxlxh)
weight
:
850 gram (without cable)
Transmitter en receiver
Modulation:
V21, V23 and Bell 103 : FSK (Frequency Shift Keying)
V27ter
:
DPSK (Differential Phase Shift Keying)
V22, V22bis, V29
:
QAM (Quadrature Amplitude
Modulation)
V32(bis), Bell212A
V17, V32, V32bis, V34
:
TCM (Trellis-Coded Modulation)
Transmission level
:
-11 dBm ± 1 dB (300-3400Hz)
:
also depending on country
requirements
Reception level
switch on
:
>-41 dBm ± 1dB
switchoff
:
<-46 dBm ± 1dB
Impedance and symmetry
Impedance
:
600
Ω
± 50
Ω
(300-3400 Hz)
:
< 200
Ω
(0Hz, 16-80 mA)
Earth symmetry
:
> 46dB
Echo muffling
:
> 15dB (300-3400 Hz)
Ring detection:
sensitivity
:
30 Veff (23-62 Hz)
switch on delay
:
180 mSec
impedance
:
> 50 k
Ω
(300-3400 Hz)
:
> 10 M
Ω
(0 Hz)
capacity
:
< 0,1m µF (25Hz)
Dialtone detection
sensitivity
:
80 mV - 2V (340-550 Hz)
waiting time
:
5 - 40 seconds
Pulse dialling
frequency
:
10Hz
duration
:
61 msec. ± 0,5%
Tone dialling (DTMF) transmission level
column
:
-10 dBm ± 1 dB
reception level row :
-12 dBm ± 1 dB
tone duration
:
75 msec. ± 5 msec.
pause duration
:
75 msec. ± 5 msec.
Electrical safety
:
Class II
TRON SECURE 33.6
Allied Data Technologies BV -
Allways one step ahead
61
Summary of Contents for TRON SECURE 33.6
Page 2: ...Allied Data Technologies BV Allways one step ahead 2 TRON SECURE 33 6...
Page 4: ...TRON SECURE 33 6 Allied Data Technologies BV Allways one step ahead 4...