S17
Reserved
S18
*
000
0-255
Test Timer
S18 is used to determine for how long a test has to be executed.
At value 0, the test will be executed continuously.
Interruption of the test has to be done with the command ATT&T0 or ATH.
S19
Reserved
S20
Reserved
S21
*
055
Bit Mapped Register
Bit
Value
Default Description
Bit 0
0-1
1
0= AT&J0 call back through line 1
1= AT&J1 call back through line 2
____________________________________________________________
Bit 1
0-1
1
0= ATK0
1= ATK1
____________________________________________________________
Bit 2
0-1
1
CTS (CT106) synchronous behaviour
0= CTS follows RTS (AT&R0)
1= CTS always on (AT&R1)
____________________________________________________________
Bit 3,4
0-3
1
DTR (CT108) behaviour
0= AT&D0 selected
1= AT&D1 selected
2= AT&D2 selected
3= AT&D3 selected
____________________________________________________________
Bit 5
0-1
0
DCD (CT109) behaviour
0= DCD always on (AT&C0)
1= DCD indicates status of the
carrier (AT&-C1)
____________________________________________________________
Bit 6
0-1
0
DSR (CT107) behaviour
0= DSR always on (AT&S0)
1= DSR on after detection reply tone
____________________________________________________________
Bit 7
0-1
0
Long Space Disconnect
0= ATY0 selected
1= ATY1 selected
____________________________________________________________
TRON SECURE 33.6
Allied Data Technologies BV -
Allways one step ahead
50
Summary of Contents for TRON SECURE 33.6
Page 2: ...Allied Data Technologies BV Allways one step ahead 2 TRON SECURE 33 6...
Page 4: ...TRON SECURE 33 6 Allied Data Technologies BV Allways one step ahead 4...
Page 6: ...Allied Data Technologies BV Allways one step ahead 6 TRON SECURE 33 6...
Page 34: ...TRON SECURE 33 6 Allied Data Technologies BV Allways one step ahead 34...