53264
47
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
66. CABINET AND BASE
a. Remove front panel. Refer to Paragraph 31,
steps “a” through “c”.
b. Remove control panel screws and lift assembly
off panel support.
c. Disconnect wire harness from all components,
and ground wire in control hood. Push harness
through hole in cabinet top. Set control panel
aside to prevent damage.
d. Remove two cabinet top hold-down screws.
Refer to Figure 26.
e. Lift front of cabinet top and disengage from
hinges on rear of cabinet. Refer to Figure 27.
Set cabinet top aside to prevent damage.
f. Remove cylinder assembly. Refer to Paragraph
60, steps “b” through “e”.
g. Disconnect wires from thermostats located on
exhaust fan cover.
NOTE: Refer to appropriate wiring diagram when
rewiring thermostats.
h. Remove two screws holding motor mounting
bracket to dryer base. Refer to Figure 29. Pull
complete assembly out through front of dryer.
i. Disconnect wires from motor switch.
NOTE: Refer to appropriate wiring diagram when
rewiring thermostats.
j. Gas Models – Remove burner housing. Refer to
Paragraph 32, steps “b” through “j”.
k. Gas Models – Remove four hex head screws
holding heat shroud to heater box and remove
shroud. Refer to Figure 16.
l. Electric Models – Remove two hex head screws
holding element and plate to heater box and
remove. Refer to Figure 25.
m. Electric Models – Disconnect wires from
element terminals and from high limit
thermostat.
NOTE: When reassembling, be sure all wire
connections are tight on element terminals and to
high limit thermostat.
n. Remove two hex head screws holding heater
box to heat shield. Refer to Figure 37.
o. Remove one Phillips head screw holding
bulkhead to terminal block bracket. While
supporting bulkhead, remove the four Phillips
head screws holding rear bulkhead to mounting
brackets. Refer to Figure 37. Lift complete
assembly out of dryer.
p. Disconnect vent and move dryer to gain access
to rear of dryer.
q. Remove two hex head screws holding heat
shield to rear of dryer cabinet. Refer to
Figure 40.
r. Remove two hex head screws from front edge
at each side of cabinet. Refer to Figure 33.
Remove remaining screws from around bottom
of cabinet and lift cabinet off base.