To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 7
Gas Burner Conversion Procedures
70. CONVERSION KITS – Glow Bar Ignition
System
All gas dryers manufactured with glow bar
ignition are factory equipped for Natural/Mixed
gas operation.
No. 56412 Natural/Mixed to L.P. Gas Kit is
available from your parts supplier. This kit
consists of:
IMPORTANT: The Conversion Kit is intended for
installation only in unused dryers. Installation
should be made by authorized Dealers or
Distributors on their premises.
NOTE: When converting the dryer gas valve to L.P.
gas, be sure the incoming gas supply line is equipped
with a pressure regulator (located ahead of the
dryer) that will maintain the gas supply to the dryer
at 11 ± 2 inches (2.74 ± .4 kPa) water column
pressure.
No. 56413 L.P. to Natural/Mixed Gas Kit is
available for field conversion. This kit consists of:
IMPORTANT: Installation of this Conversion Kit
must be made by a qualified serviceman, or an
Authorized Dealer or Distributor.
NOTE: When converting the dryer gas valve to
Natural Gas, be sure the incoming gas supply line is
equipped with a pressure regulator (located ahead
of the dryer) that will maintain the gas supply to the
dryer at 7 ± 2 inches (1.74 ± .5 kPa) water column
pressure.
71. ORIFICE INFORMATION
WARNING
This conversion kit is to be installed by AUTHORIZED DEALERS or DISTRIBUTORS on their
premises and in accordance with the manufacturer’s instructions and all codes and
requirements of the authority having jurisdiction. Failure to follow instructions could result in
serious injury or property damage. The qualified agency performing this work assumes
responsibility for this conversion.
W312
1 - 51211
Burner Orifice Spud
1 - 53390
Block-Open Plug and Gasket
1 - 53408
Change-Over Sticker
1 - 55753
“Valve Converted” Sticker
2 - 56426
L.P. Gas Stickers
1 - 50326
Burner Orifice Spud
1 - 53556
Change-Over Sticker
1 - 53952
Vent Screw and Gasket
1 - 56414
Valve Number Sticker
2 - 56427
Natural Gas Stickers
Burner
Orifice
Kind
of Gas
Part
Number
Stamp
Code
Natural/Mixed
50326
44
Liquefied
Petroleum (L.P.)
51211