50
53264
Section 6 Adjustments
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
69. BURNER FLAME (Gas Models)
a. Close loading door, set fabric selector switch at
NORMAL, set timer at “65”, and push start
switch button to start dryer.
b. Allow dryer to operate for approximately five
minutes, then open access door and loosen air
shutter lockscrew. Refer to Figure 42.
c. Turn air shutter to the right or left to obtain a
soft, uniform blue flame. (A lazy, orange-
tipped flame indicates lack of air. A harsh,
roaring, very blue flame indicates too much
air.)
d. After proper flame is obtained, tighten air
shutter lockscrew securely. Refer to Figure 42.
Figure 42
DRY855S
SHUT-OFF VALVE
HANDLE
AIR SHUTTER
LOCKSCREW
1/8” (3.1 mm)
PIPE PLUG
(For checking
manifold
pressure)
AIR
SHUTTER
BURNER
TUBE
SCREW
APPLY
VALVE CONVERTED
OR VALVE NUMBER
STICKER HERE