53264
19
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 5
Service Procedures
IMPORTANT: When reference to direction (right
or left) is made in this manual, it is from the
operator’s position facing the front of the dryer.
20. TIMER — ALL MODELS
Refer to Figures 8, 9 or 10 for timer removal.
NOTE: When timer knob is installed, adjust
indicator. Refer to Paragraph 67.
21. TEMPERATURE SELECTOR SWITCH
Refer to Figures 8, 9 or 10 for switch removal.
To Test Timer Contact Points
Refer to Figure 7
1. All models: Remove panel screws and lift
assembly off panel support. Refer to Figures 8,
9 or 10.
2. Disconnect wires from timer.
NOTE: Refer to appropriate wiring diagram
when rewiring timer.
3. Set meter to read Ohms and put meter probes to
terminals:
a. L1 and M to test Drive Motor circuit.
b. L2 and H to test Heat circuit
c. L2 and T to test Timer Motor circuit.
d. B and P to test Buzzer circuit.
NOTE: 52594 Timer ONLY
L1 to H to test for Heat circuit
L1 to M to test for Motor and Timer
Motor circuit.
4. Starting with timer knob indicator in OFF
position at top of timer, slowly turn timer knob
clockwise until indicator is again pointing
toward OFF position at top of timer. Meter
should register “zero” reading when circuit
being tested is completed by timer. Refer to
appropriate wiring diagram for Timer Cycle
Chart showing when circuit is made.
Figure 7
DRY840S
T
L2
H
B
L1
P
N
M
To Test Temperature Selector Switch:
1. Remove control panel. Refer to Figures 8, 9 or
10. Lift assembly off panel support.
2. Disconnect wires from switch.
NOTE: Refer to appropriate wiring diagram
when rewiring switch.
3. Set meter to read Ohms and put meter probes on
switch terminals by following the appropriate
wiring diagram for your model dryer.