53264
29
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
b. Burner tube and igniter
NOTE: Burner tube and igniter can be removed
without removing gas valve and bracket.
(1) Remove one screw from right side of
burner housing holding burner tube in
place. Refer to Figure 14.
(2) Gently move burner tube toward rear of
dryer to disengage tab from slot on left side
of burner housing. Refer to Figure 16.
(3) Carefully rotate burner tube and igniter
counterclockwise so tab is at 8 o’clock
position.
(4) Move air shutter end of burner tube slightly
to right and CAREFULLY remove burner
tube and igniter assembly out through front
of dryer.
c. Igniter. Refer to Figure 17
(1) Remove burner tube and igniter, paragraph
30, section b, steps 1 through 4.
(2) Carefully remove igniter by spreading
mounting clips with a Tru-Arc pliers.
Figure 16
D397S
BURNER
TUBE
SCREW
HIGH LIMIT
THERMOSTAT
HEX HEAD
SCREW
HEAT
SHROUD
UNION
NUT
SENSOR
VALVE
BURNER
HOUSING
Use care in removal so as not to damage or
break igniter as it is very fragile.
CAUTION
Figure 17
Handle igniter by grasping white ceramic
portions only. DO NOT handle silicon
carbide portion of igniter with hands or
allow any oil, grease or other foreign
material to contaminate it. Oil, grease and
other impurities or hairline cracks will cause
igniter to burn out.
WARNING
DRY847S
BURNER
TUBE
MOUNTING
CLIP
55438
IGNITER
Use care in removal so as not to damage or
break igniter as it is very fragile.
CAUTION