70143101
35
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
STAND ALONE TUMBLE DRYER
a. Remove gas valve cover. Refer to
b. Disconnect gas valve wire connections.
c. Disconnect gas valve pipe union holding gas
shut-off valve to gas valve nipple.
d. Remove screws holding gas valve to gas valve
bracket and remove valve.
IMPORTANT: When reinstalling gas valve, purge
air and sediment from gas service line before
connecting to tumble dryer. Purge remaining air
until odor of gas is detected, then tighten
connection. Use pipe compound resistant to action
of L.P. gas on all pipe threads.
To reduce risk of fire or explosion, check
pipe connections for gas leaks with a non-
corrosive leak detection fluid. Do not use an
open flame to check for gas leaks!
W310
WARNING
Figure 25
T297SE1A
GAS
VALVE
MANUAL
SHUT-OFF
VALVE
CLOSE
NIPPLE
UNION
PIPE
NIPPLE
ELBOW
ADAPTER
GAS VALVE
ATTACHING
SCREW
GAS
VALVE
BRACKET