Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
34. BURNER TUBE ASSEMBLY
a. Remove complete gas valve assembly. Refer to
b. Remove stove guard screws holding stove
guard to bottom of stove and remove guard.
c. Remove screws holding burner to stove.
d. Remove burner by sliding burner tube away
from gas valve end of stove.
e. Pull down on gas valve end of burner tube and
remove from bottom of stove.
35. VIEWER WINDOW
a. Loosen screw in upper left corner.
b. Remove lower screw.
c. Turn plate counterclockwise in order to view
burner tube and igniter gap.
36. IGNITER ASSEMBLY
a. Remove screws holding gas valve cover to
stove and remove cover. Refer to
.
b. Remove two screws holding igniter to stove
and remove igniter.
IMPORTANT: When reinstalling igniter to burner,
gap should be .110" - .140" (2.79 - 3.55 mm). Refer
Figure 26
TMB36S
TMB36S
BURNER
TUBE
ASSEMBLY
VIEWER
WINDOW
STOVE
GUARD
STOVE
GUARD
SCREWS
IGNITER
SCREW
IGNITER
SCREW
Figure 27
T276SE1C
Burner
Tube
I
g
niter
Assembly
Gap
.110 inch - .140 inch
(2.79 - 3.55 mm)