![Alliance Laundry Systems AT0350SRG Service Manual Download Page 41](http://html1.mh-extra.com/html/alliance-laundry-systems/at0350srg/at0350srg_service-manual_2901264041.webp)
70143101
39
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
38. THERMISTOR
STACKED TUMBLE DRYER
a. Remove screws holding guard to blower
housing.
b. Disconnect wires to thermistor.
c. Unscrew thermistor by turning
counterclockwise.
NOTE: Do not turn thermistor by spade terminals.
STAND ALONE TUMBLE DRYER
a. Remove screws holding guard to tumble dryer
and remove cover.
b. Disconnect wires to thermistor.
c. Unscrew thermistor by turning
counterclockwise.
NOTE: Do not turn thermistor by spade terminals.
IMPORTANT: Do not damage thermistor during
removal.
Figure 30
T270SE3A
THERMISTOR
BLOWER
HOUSING
GUARD
CABINET
THERMOSTAT