To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 6
Adjustments
48. LEVELING LEGS
NOTE: Keep the tumble dryer as close to the floor
as possible. All legs must rest firmly on the floor so
weight of tumble dryer is evenly distributed.
Tumble dryer must not rock.
a. Check front to rear level by rotating clothes
cylinder until one of the cylinder ribs is at the
bottom. Place a level on the rib. Adjust legs as
necessary.
NOTE: The front of the tumble dryer should be
slightly higher than the rear (approximately 1/8
inch, 3.18 mm). This will prevent the clothes, while
tumbling, from wearing on the door glass gasket.
b. Check side to side level by placing a level on
front and rear of top panel. Adjust legs as
necessary.
IMPORTANT: Do not remove plastic caps covering
leveling legs in lint compartment.
STACKED TUMBLE DRYER ONLY
a. Level four main legs and then run fifth leg to
floor and secure.
49. AIRFLOW SWITCH ADJUSTMENT
The airflow switch is set at the factory for proper
operation. No adjustment necessary.
Figure 44
The stacked drying tumbler has a 5th
leveling leg on the blower housing. It is very
important to properly adjust this leg. Unit is
back heavy and could rock or tip.
W250
WARNING
T467IE1A
Fifth
Le
g