70143101
33
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
32. STOVE HIGH LIMIT THERMOSTAT
a. Remove cover screws holding gas valve cover
to stove and remove cover.
b. Disconnect wires from stove limit thermostat.
NOTE: Refer to wiring diagram when rewiring
thermostat.
c. Remove screws holding stove limit thermostat
to stove.
Stacked Tumble Dryer
Stand Alone Tumble Dryer
Figure 23
TMB34S
60%
TMB34S
STOVE LIMIT
THERMOSTAT
COVER
SCREW
GAS VALVE
COVER
THERMOSTAT
ATTACHING
SCREW
TMB35S
75%
TMB35S
STOVE
LIMIT
THERMOSTAT
THERMOSTAT
ATTACHING
SCREW
STOVE