Rockwell Automation Publication 2097-UM001D-EN-P - November 2012
185
Interconnect Diagrams
Appendix A
Motor Brake Currents
Use these coil current values to size the interposing relay required for your
application. See the interconnect diagram for your Kinetix 300 drive/motor
beginning on
for typical motor brake circuitry.
Table 68 - Motor Brake Coil Currents
Compatible Brake Motors/Actuators
(1)
(1) Use of the variable x indicates this specification applies to 230V and 460V motors.
Coil Current
MPL-
x
1510, MPL-
x
1520, MPL-
x
1530
0.43…0.53 A
MPL-
x
210, MPL-
x
220, MPL-
x
230
0.46…0.56 A
MPL/MPF-
x
310, MPL/MPF-
x
320, MPL/MPF-
x
330
0.45…0.55 A
MPM-
x
115
MPS-
x
330
MPL-
x
420, MPL-
x
430, MPL-
x
4520, MPL-
x
4530, MPL-
x
4540,
MPL-B4560
0.576…0.704 A
MPM-
x
130
MPF-
x
430, MPF-
x
4530, MPF-
x
4540
MPS-
x
4540
TLY-A110T, TLY-A120T, and TLY-A130T
0.18…0.22 A
TLY-A220T and TLY-A230T
0.333…0.407 A
TLY-A2530P, TLY-A2540P, and TLY-A310M
0.351…0.429 A