Rockwell Automation Publication 2097-UM001D-EN-P - November 2012
173
Interconnect Diagrams
Appendix A
Power Wiring Examples
You must supply input power components. The single-phase and three-phase line
filters are wired downstream of fusing and the M1 contactor.
In this example, the 2097-V31PR
x
drives are wired to use the voltage doubling
circuit. The 120V input voltage provides 240V output to motors. The 2097-
V33PR
x
drives are wired for single-phase 120V operation.
Figure 83 - Kinetix 300 Drive (120V single-phase input power)
PE
N
L1
+24V DC
+
+
SH
-
-
EN
ACOM
RDY +
RDY -
L1
L2/N
29
26
41
42
U
V
W
PE
L2/N
PE
L2
L3
L1
2097-V31PRx
2097-V33PRx
Return
Single-phase AC Input
120V rms AC, 50/60 Hz
Notes 1, 2
Bonded Cabinet
Ground Bus *
Ground Stud
Mains
Single-phase
AC Input
(IPD) Connector
Fuse Disconnect
or Circuit Breakers
Input Fusing *
M1 *
Notes 5, 7
Use discrete logic or PLC
to control ENABLE to drive
and monitor RDY signal
back from drive.
Shunt Resistor
and DC Bus
(BC) Connector
Motor Power
(MP) Connector
I/O (IOD)
Connector
Back-up Power
(BP) Connector
2097-V31PR
x
and 2097-V33PR
x
Kinetix 300 Drives
* Indicates User Supplied Component
See table on
page 172
for note information.
AC Line Filter
(Optional)
Note 3
Three-phase
Motor Power
Connections
Note 9
Cable Shield
Clamp
Note 8
Shunt Resistor
Connections
User-supplied
+24V DC