152
Rockwell Automation Publication 2097-UM001D-EN-P - November 2012
Chapter 6
Configure and Start Up the Kinetix 300 Drive
If you choose auto phasing, the following appears.
13.
Follow the instructions in the dialog box.
If your system is wired by using one of the interconnect diagrams in
, then you get the following results.
Parameter Value
Resolution (x1)
20 μm
Resolution (x4)
5 μm
Halls order
3
Inverted
Checked
B lead A for forward
Unchecked