Publication 1756-UM522B-EN-P - February 2003
1756-DMF30 Specific Information C-59
1098
SL Buf Real Rx12
Displays the floating point (real) value of the Buffered
Received Data for word 12. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1097 [SL Buf Int R12].
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Non-Linkable, Read-Only, Floating Point
SynchLink
Buffered Data In
1099
SL Buf Int Rx13
Displays the integer value of the Buffered Received Data for
word 13. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1100 [SL Buf Real R13].
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable, Read-Only, 32-Bit Integer
SynchLink
Buffered Data In
1100
SL Buf Real Rx13
Displays the floating point (real) value of the Buffered
Received Data for word 13. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1099 [SL Buf Int R13].
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Non-Linkable, Read-Only, Floating Point
SynchLink
Buffered Data In
1101
SL Buf Int Rx14
Displays the integer value of the Buffered Received Data for
word 14. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1102 [SL Buf Real R14].
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable, Read-Only, 32-Bit Integer
SynchLink
Buffered Data In
1102
SL Buf Real Rx14
Displays the floating point (real) value of the Buffered
Received Data for word 14. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1101 [SL Buf Int R14].
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Non-Linkable, Read-Only, Floating Point
SynchLink
Buffered Data In
1103
SL Buf Int Rx15
Displays the integer value of the Buffered Received Data for
word 15. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1104 [SL Buf Real R15].
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable, Read-Only, 32-Bit Integer
SynchLink
Buffered Data In
1104
SL Buf Real Rx15
Displays the floating point (real) value of the Buffered
Received Data for word 15. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1103 [SL Buf Int R15].
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Non-Linkable, Read-Only, Floating Point
SynchLink
Buffered Data In
1105
SL Buf Int Rx16
Displays the integer value of the Buffered Received Data for
word 16. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1106 [SL Buf Real Rx16].
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable, Read-Only, 32-Bit Integer
SynchLink
Buffered Data In
No.
Name
Description
Values
Summary of Contents for ControlLogix 1756-DMD30
Page 1: ...ControlLogix Drive Module 1756 DMD30 1756 DMF30 User Manual y...
Page 4: ......
Page 8: ...Publication 1756 UM522B EN P February 2003 4...
Page 10: ...Publication 1756 UM522B EN P February 2003 Summary of Changes 2 Notes...
Page 14: ...Publication 1756 UM522B EN P February 2003 Preface 4 Notes...
Page 26: ...Publication 1756 UM522B EN P February 2003 2 4 Drive Comm Drive Communication Notes...
Page 44: ...Publication 1756 UM522B EN P February 2003 4 8 Installing the Drive Module Notes...
Page 252: ...Publication 1756 UM522B EN P February 2003 B 172 1756 DMD30 Specific Information Notes...