Publication 1756-UM522B-EN-P - February 2003
B-84 1756-DMD30 Specific Information
618
Integer In09
Displays input word 09 of the controller communication format
in integer format. Paired with parameter 619 [Real In09],
which displays the same data in floating point format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Communication
Logix Inputs
619
Real In09
Displays input word 09 of the controller communication format
in floating point format. Paired with parameter 618 [Integer
In09], which displays the same data in integer format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
Communication
Logix Inputs
620
Integer In10
Displays input word 10 of the controller communication format
in integer format. Paired with parameter 621 [Real In10],
which displays the same data in floating point format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Communication
Logix Inputs
621
Real In10
Displays input word 10 of the controller communication format
in floating point format. Paired with parameter 620 [Integer
In10], which displays the same data in integer format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
Communication
Logix Inputs
622
Integer In11
Displays input word 11 of the controller communication format
in integer format. Paired with parameter 623 [Real In11],
which displays the same data in floating point format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Communication
Logix Inputs
623
Real In11
Displays input word 11 of the controller communication format
in floating point format. Paired with parameter 622 [Integer
In11], which displays the same data in integer format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
Communication
Logix Inputs
624
Integer In12
Displays input word 12 of the controller communication format
in integer format. Paired with parameter 625 [Real In12],
which displays the same data in floating point format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Communication
Logix Inputs
625
Real In12
Displays input word 12 of the controller communication format
in floating point format. Paired with parameter 624 [Integer
In12], which displays the same data in integer format.
Default:
Min:
Max:
Type:
File:
Group:
0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
Communication
Logix Inputs
No.
Name
Description
Values
Summary of Contents for ControlLogix 1756-DMD30
Page 1: ...ControlLogix Drive Module 1756 DMD30 1756 DMF30 User Manual y...
Page 4: ......
Page 8: ...Publication 1756 UM522B EN P February 2003 4...
Page 10: ...Publication 1756 UM522B EN P February 2003 Summary of Changes 2 Notes...
Page 14: ...Publication 1756 UM522B EN P February 2003 Preface 4 Notes...
Page 26: ...Publication 1756 UM522B EN P February 2003 2 4 Drive Comm Drive Communication Notes...
Page 44: ...Publication 1756 UM522B EN P February 2003 4 8 Installing the Drive Module Notes...
Page 252: ...Publication 1756 UM522B EN P February 2003 B 172 1756 DMD30 Specific Information Notes...